closed

Poor diagnostics when license file expired

Added by Michael Kay almost 10 years ago. Updated almost 10 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
Diagnostics
Sprint/Milestone:
-
Start date:
2014-05-05
Due date:
% Done:

100%

Estimated time:
Legacy ID:
Applies to branch:
Fix Committed on Branch:
Fixed in Maintenance Release:
Platforms:

Description

When running from the command line and loading configuration details from a configuration file using the -config option, Saxon produces poor diagnostics if it has found that the license file has expired. Specifically, it falls back to unlicensed mode (that is, Saxon-HE capability) and reports an error only if functionality that requires a license is then requested. For example, if there is a call to an extension function only available in Saxon-PE or higher, Saxon will simply report that the extension function could not be found.

Actions #1

Updated by Michael Kay almost 10 years ago

  • Status changed from In Progress to Resolved

Patch raised which causes fatal license problems (as distinct from "no license found") to be reported immediately.

Actions #2

Updated by O'Neil Delpratt almost 10 years ago

  • Status changed from Resolved to Closed
  • % Done changed from 0 to 100
  • Fixed in version set to 9.5.1.6

Bug fix applied in Saxon maintenance release 9.5.1.6