Project

Profile

Help

Bug #1644

closed

"FORG0006: Effective boolean value is not defined" for a TEI transformation with byteCodeGeneration ON

Added by Alex Jitianu over 11 years ago. Updated about 11 years ago.

Status:
Closed
Priority:
Low
Category:
Byte code generation
Sprint/Milestone:
-
Start date:
2012-11-13
Due date:
% Done:

100%

Estimated time:
Legacy ID:
Applies to branch:
Fix Committed on Branch:
Fixed in Maintenance Release:
Platforms:

Description

Hi,

We stumbled upon the following exception while running a TEI (Text Encoding Initiative) transformation with Saxon 9.4.0.6 EE with byte code generation ON:

Error on line 1338 of RngToRnc.xsl:
  FORG0006: Effective boolean value is not defined
Transformation failed: Run-time errors were reported

To reproduce it you first have to download the TEI stylesheets v6.19 available at http://sourceforge.net/projects/tei/files/Stylesheets/. After that, just run a transformation on the attached XML file using as XSL: tei-xsl-6.19/xml/tei/stylesheet/odds2/odd2lite.xsl. The transformation will fail with the above error message.

The transformation succeeds when byte code generation is disabled. I'm sorry I didn't succeeded in creating a smaller example to reproduce the issue.